AC Induction Motor Selector

Power · Start · Real motors · Starter

Work out the shaft power a conveyor, pump, fan or hoist needs, describe how it starts and how it is used, and shortlist real Bonfiglioli induction motors that pass. Each motor is checked for power, speed, starting torque, start time, starts per hour, brake and efficiency class, and then matched to a starter or VFD rating.

This is a first selection for a single motor on a 400 V, 50 Hz supply. It does not replace the maker’s selection, which also checks the speed-torque curve, the voltage and winding, the cooling and the mounting. Motor data are Bonfiglioli catalogue figures; other brands are not loaded yet, and the starter and VFD ratings are general rules, not product data.

00

Start Here: Choosing an Induction Motor

A three-phase induction motor is chosen on four things, not one: the power the load needs at its speed, whether the motor can start the load, how long it takes to run up to speed, and how often it can start without overheating. These six steps give the order. Read them once, then use sections 01 to 05.

1

Find the power the load needs

Work out the shaft power from the machine: a conveyor, a pump, a fan, a hoist or a known torque and speed. Use the calculators and worked examples.

Start in section 01 →
2

Describe the start and the duty

How hard the load is to start, how much inertia it has, how often it starts, the ambient temperature and how you want to start it: direct, star-delta, soft starter or VFD.

Fill section 02 →
3

Let the tool shortlist real motors

Each motor is checked for power, speed, starting torque, start time, starts per hour, brake and efficiency class. Only motors that pass are listed, smallest first.

Find a motor in section 03 →
4

Size the starter or drive

Pick one of the passing motors to see the contactor, overload and soft-starter or VFD current it needs.

See section 04 →
5

Know what the start method does

A star-delta start cuts the current to a third, but it also cuts the torque to a third. Read the comparison before you choose.

Compare in section 05 →
6

Confirm before you order

Check the speed-torque curve, the winding and the exact order code with the maker. This page is a first selection, not a maker’s quotation.

Common mistakes

Choosing on kilowatts aloneA motor that carries the load at speed may still not start it. Check the starting torque, and the time it takes to reach speed with the load inertia.
Forgetting slipA 4-pole motor is called 1,500 rpm, but it runs at about 1,400 to 1,490 rpm under load. A pump or fan uses the cube of speed for power, so a few percent more speed needs more power.
Star-delta on the wrong windingStar-delta starting on a 400 V supply needs a motor wound 400 V in delta. Small frames are wound 230/400 V and cannot be started this way. Check the nameplate voltage.
Starting a heavy inertia direct on lineA big flywheel or fan takes many seconds to accelerate. All that time the motor draws about six times its rated current and heats up. Check the start time and the starts per hour.
Believing star-delta is gentle on the loadIt cuts the starting torque to one third. A load with high breakaway torque may not move at all in star, and then jumps when the starter changes to delta.
Ignoring ambient temperatureCatalogue powers are for 40 °C ambient and up to 1,000 m. At 50 °C Bonfiglioli allows 90 % of the rated power.
Slow running on a VFD with a fan-cooled motorAt low speed the shaft fan moves less air. The catalogue says standard motors need torque derating, or a separate fan, at about 30 Hz and below.
Hoists and liftingA brake motor is not enough for lifting. The catalogue asks you to contact the maker for lifting and for high hourly braking energy.

Brands that make this product

Outlined gold: motor data loaded from the maker’s catalogue (Bonfiglioli). Grey dashed: not loaded yet. Confirm every model against the maker’s catalogue before you order.

Bonfigliolimotor dataABBnot yetSiemensnot yetCROMPTON GREAVESCrompton Greavesnot yetSEW-Eurodrivenot yetNordnot yet
See all hardware and brand coverage

Brand names and logos are trademarks of their owners and are shown only to identify catalogues.

01

Required Power

Everything starts from the power the load takes at the motor shaft. Pick the load type to see the formula, a worked example and a button that fills the example values. The result goes into the field at the bottom, which you can also type into directly.

Worked example for this load type

A belt conveyor carries a total of 5,000 kg at 1 m/s. Rollers and belt friction give a coefficient of about 0.04, the belt is flat, and the gearbox and belt are 85 % efficient. The force is 5,000 × 9.81 × 0.04 = 1,962 N, so the shaft power is 1,962 × 1 ÷ 0.85 = 2.3 kW. A conveyor is a constant-torque load.

A centrifugal pump delivers 60 m³/h of water against a 30 m head, and the pump is 65 % efficient. The shaft power is 1,000 × 9.81 × (60 ÷ 3,600) × 30 ÷ 0.65 = 7.5 kW. A pump is a quadratic-torque load: its torque rises with the square of the speed, so it starts easily.

A fan moves 12,000 m³/h against 800 Pa, and the fan is 65 % efficient. The shaft power is (12,000 ÷ 3,600) × 800 ÷ 0.65 = 4.1 kW. A fan is also a quadratic-torque load, but a large fan has a large inertia, so check the start time.

A hoist lifts 500 kg at 0.2 m/s with an 80 % efficient drive, so the shaft power is 500 × 9.81 × 0.2 ÷ 0.8 = 1.2 kW. This is the running power only. A hoist must also be held by a brake and needs the maker’s advice.

A mixer needs 40 N·m at the motor shaft at 1,440 rpm. The power is 40 × 1,440 ÷ 9,550 = 6.0 kW.

You already know the shaft power (for example from a machine drawing): 5.5 kW. Skip the calculators and type it in the field below.

kg, load on the belt plus belt parts
m/s
about 0.02 to 0.06 for belts on rollers (assumed, confirm)
degrees, 0 is flat
N, scrapers or pushing force
%, gearbox and belt (assumed, confirm)
m³/h
m, including pipe losses
kg/m³, water is 1,000
%, from the pump curve
m³/h
Pa
%, from the fan curve
kg
m/s
%
N·m
rpm
kW
Shaft power the load needs—

kW, at the speed below
rpm. For a motor on a 50 Hz supply this is just under 3,000, 1,500, 1,000 or 750.
How far the motor’s rated speed may differ from your speed
How the load torque changes with speed
Added on top of the load power
02

Starting and Duty

Starting is where induction motors fail. Describe how hard the load is to start, how heavy it is to accelerate, how you will start it and how the motor will be used. Each field has a default you can change.

kg·m². Use the calculator below. A small fan or pump may be 0.01 to 0.1.
% of the full-load torque. About 150 for a loaded conveyor, 20 for a fan or pump.
See section 05 for what each does
Don’t know the load inertia? Calculate it

Inertia is how hard a rotating part is to speed up. Enter the part that turns, and the gear ratio between the motor and that part. The result is reflected to the motor shaft, because the motor sees the inertia divided by the ratio squared. Use Add to build up several parts one at a time.

Used for the cylinder only.
mm
mm
kg
mm
1 if the part is on the motor shaft, 10 for a 10 : 1 reducer
Inertia—

% of line voltage at the start. The torque falls with its square. Used only for a soft starter.
% of rated torque. A typical limit for a short start (assumed, check your drive). Used only for a VFD.
The supply sags when the motor starts. Torque falls with its square
A long start heats the rotor. Ask the maker for starts longer than about 10 s
How many times it starts in an hour
%. The share of the cycle the motor is running. 50 % is the catalogue basis.
Continuous duty is S1. The catalogue gives power factors for S2 and S3
Catalogue powers are for 40 °C
m above sea level. The catalogue is for up to 1,000 m and gives no figure above.
Spring-applied, fail-safe. FD is DC, FA is AC
N·m at the motor shaft. 0 if it is only a parking or stopping brake.
On the hold torque. Your own rule, not from the catalogue.
IE3 is premium. In the EU, motors from 0.75 kW up must be IE3 or IE2 with a VFD (see section 06)
4 poles is about 1,500 rpm, 2 about 3,000
03

Find a Motor

The tool tests each Bonfiglioli motor against sections 01 and 02. It takes the catalogue’s rated power, rated speed, current, efficiency, starting torque and inertia, then works out the power used, the start time, the inrush current and the starts per hour. Passing motors are listed smallest first.

04

Starter or VFD for the Chosen Motor

Pick one of the passing motors. The table shows the contactor, overload and drive current each start method needs. These come from standard IEC practice and the motor’s rated current. They are not catalogue figures for a particular starter brand.

The list is the motors that pass in section 03.
05

What Each Start Method Does

Torque and current are shown as a share of the direct-on-line values. The tool uses these factors in section 03. The VFD figure is an assumption you can change in section 02.

MethodTorque factorCurrent factorInrushWhat it doesUse it for
Direct on line116 to 9 times the rated currentSimple and cheap. Full torque. Hard on the supply and the machine.Small motors, light starts, a strong supply.
Star-delta1/31/3About 2 to 3 times the rated currentStarts in star, then switches to delta. Torque and current are one third. A jolt at the changeover.Light loads (unloaded or fans and pumps) where the supply is weak. Needs a 400 V delta winding.
Soft starterk² (k is the start voltage)kSet by the start voltageRamps the voltage. Smooth, adjustable, no changeover. Torque falls with the square of the voltage.Conveyors, pumps and fans where smooth starting matters.
VFDAbout 1.5 (limited by the drive)About 1.5 (limited by the drive)Close to the rated currentGives full control of acceleration and speed. Needs motor cooling at low speed and costs more.Speed control, many starts, long runs at partial speed.

The torque factor is applied to the catalogue’s starting torque (Ms) and mean accelerating torque (Ma). The voltage dip you set in section 02 is applied as well, squared. The catalogue gives the locked-rotor current as a multiple of the rated current (Is/In), 6 to 9 times for most motors.

06

Reference Tables

Ambient temperature and power

Ambient temperatureAllowed power, % of rated
40 °C or lower100
45 °C95
50 °C90
55 °C85
60 °C80

Bonfiglioli’s table, for up to 1,000 m. For a derating above 15 %, the maker asks you to consult them.

Power factor for short-time and intermittent duty

Duty10 min or 25 %30 min or 40 %60 min or 70 %
S2, limited time1.351.151.05
S3, intermittent1.251.151.1

A motor may carry the rated power times this factor for the duty shown. S3 cycles must not exceed 10 minutes. For S4 to S9, contact the maker.

Starts-per-hour load factor, Kd

Load, Pr / PnKd at 15 % dutyKd at 50 %Kd at 100 %
0.30.610.740.92
0.40.590.700.84
0.50.580.650.76
0.60.560.600.65
0.70.550.540.52
0.80.530.460.36
0.90.500.370.19
1.00.470.280.00

The catalogue prints Kd only as a chart. These values were read from the straight lines of the chart and are good to about ± 0.03. The tool interpolates between them. The permitted starts per hour are Z = Z0 × Kc × Kd ÷ KJ, with KJ = (Jm + Jc) ÷ Jm and Kc = (Ma − ML) ÷ Ma.

Efficiency classes

ClassNameWhat the regulation requires
IE1Standard efficiencyAllowed outside the EU rules. Bonfiglioli BN motors are the IE1 range; not every BN size carries an IE1 mark.
IE2High efficiencyEU minimum from 16 June 2011. Also the minimum when the motor is on a VFD.
IE3Premium efficiencyEU minimum for 7.5 to 375 kW from 1 January 2015, and for 0.75 to 375 kW from 1 January 2017 (IE2 if fed by a VFD).

From the catalogue’s summary of EC Regulation 640/2009, which covers 2, 4 and 6-pole single-speed 50 or 60 Hz cage motors of 0.75 to 375 kW for continuous duty. It does not cover brake motors. Check the current regulation for your country.

Formulas used

QuantityFormula
Rated torqueMn (N·m) = 9,550 × P (kW) ÷ n (rpm)
Synchronous speedns = 120 × f ÷ poles. 3,000, 1,500, 1,000, 750 rpm at 50 Hz
Start timet = (Jmotor + Jload) × 2πn ÷ 60 ÷ (Ma − ML,mean)
Mean load torque while acceleratingConstant-torque load: ML. Fan or pump: about ML ÷ 3
Load torque of a fan or pumpTorque rises with speed squared, power with speed cubed
07

Explanatory Notes

How the shortlist works

For each motor the tool first applies the ambient and duty factors to the rated power and compares it with your load power (at the motor’s own speed, plus your margin). It then checks the speed, the starting torque against the load’s breakaway torque (plus 10 %), and the mean accelerating torque against the mean load torque. The start time follows from the motor and load inertia. Starts per hour use the catalogue formula. The brake, efficiency class and pole filters apply last.

What the catalogue prints

Bonfiglioli prints, for each motor at 400 V and 50 Hz: rated speed, torque and current, efficiency at 100, 75 and 50 % load (BN 8-pole at 100 % only), power factor, locked-rotor current (Is/In), starting torque (Ms/Mn), a torque ratio Ma/Mn, rotor inertia and mass. The catalogue calls Ma the mean breakaway torque. It is always lower than Ms, so the tool treats it as the mean torque available while accelerating. That is the safe reading. It prints no pull-out (maximum) torque, so the tool cannot check a load peak.

Which motors are loaded

157 single-speed motors at 400 V and 50 Hz. BX (IE3, 4 poles, 0.75 to 355 kW, including the cast-iron K frames from 30 kW), BE (IE2, 2, 4 and 6 poles, up to 22 kW) and BN (IE1 range, 2, 4, 6 and 8 poles, up to 30 kW). BX is only listed with 4 poles in this catalogue, so for an IE3 2 or 6-pole motor there is no match here. Dual-speed motors, 60 Hz and NEMA data, and motors for other voltages are not loaded.

Brake motors

The brake tables give the brake torque, the rotor inertia with the brake, and the permitted starts per hour. In some BE and BN rows the printed inertia with brake is lower than the plain motor, and the tool uses it as printed. DC brakes have normal (NB) and fast (SB) rectifiers with different starts per hour. The tool uses the normal figure, or the fast one where it is the only one printed. BX motors have no starts-per-hour figure, and for them the check shows n/a.

Starts per hour

Z0 in the catalogue is for 50 % duty and no load. The tool takes it from the brake version of the same motor, even if you chose no brake, and says so by showing it in the starts column. The Kd factor is read from a chart, so the result is approximate. If you need more than a few starts an hour, ask the maker.

Printed value left out

The BE 112M 4-pole row printed at 3.7 kW shows 27 N·m torque, which is the figure for the 4 kW motor on the same frame (3.7 kW at 1,445 rpm is 24.5 N·m). The tool leaves that row out and keeps the 4 kW row.

Star-delta and the winding

The catalogue lists 230/400 V motors as standard up to frame 132, and 400/690 V from frame 160. On a 400 V supply, star-delta starting needs the 400/690 V winding. So the tool removes the smaller frames when you choose star-delta. A 230/400 V motor can still be soft-started or run on a VFD.

VFD assumptions

The 150 % starting torque from a VFD, and the starter and drive current rules in section 04, are common practice and not catalogue data. Bonfiglioli says its standard motors may be used with PWM inverters up to 500 V at the transformer input, and that standard fan-cooled motors need torque derating, or a separate fan, at about 30 Hz and below. The derating curve is not loaded. The catalogue also lists maximum speeds above base frequency, for example 4,000 rpm for 4-pole BX 80 to 180.

Hoists, altitude and other limits

The catalogue asks you to contact the maker for lifting, for high hourly braking energy and for S4 to S9 duty. It gives no derating above 1,000 m, and no figure for high inertia loads beyond the starts formula. The tool leaves these to the maker.

Gearmotor catalogues

Nine other Bonfiglioli files were supplied. They cover gearboxes and gearmotors (C, VF-W, HDP, 3/H, TIR planetary, the ATEX and AS ranges). They rate the gearbox output, and are not used by this tool. They will suit a gearmotor selector.

Not loaded

ABB, Siemens, Crompton Greaves, SEW-Eurodrive and Nord. Their motors will be added as their catalogues are provided. Starter and VFD makers’ own products are not loaded either, so section 04 gives ratings, not part numbers.

08

Sources

All motor figures were read from the Bonfiglioli BN-BE-BX catalogue in October 2026. They are for 400 V, 50 Hz, S1 duty, and the maker’s tolerances apply. Confirm the order code and the current revision with Bonfiglioli before you order.

Motors

Bonfiglioli, Three-phase asynchronous motors BN-BE-BX Series, catalogue BR_CAT_BNEX_STD_ENG R06: motor rating charts BX (printed pages 58 to 62), BE (75 to 81) and BN (88 to 97).

Rules

The same catalogue: section 6.3 ambient temperature (table F20), 6.12 type of duty (table F26), 6.13 inverter-controlled motors, 6.14 permissible starts per hour with figure F29, section 2 efficiency classes, and the voltage table in section 6.1.

Standards

IEC 60034-1 (ratings and duty), IEC 60034-30-1 (efficiency classes) and EC Regulation 640/2009, as summarised in the catalogue. IEC 60947-4-1 for contactors and overload relay classes, as general practice.